Task #12843 (closed)
Bug: incorrect dimensions used for some .czi tiles
Reported by: | mlinkert | Owned by: | mlinkert |
---|---|---|---|
Priority: | major | Milestone: | 5.1.2 |
Component: | Bio-Formats | Version: | 5.1.0 |
Keywords: | ZeissCZIReader, our-fault | Cc: | sebrhode@… |
Resources: | n.a. | Referenced By: | n.a. |
References: | n.a. | Remaining Time: | 0.0d |
Sprint: | n.a. |
Description
See http://lists.openmicroscopy.org.uk/pipermail/ome-users/2015-April/005294.html
The exception does not occur with 5.1.0/5.0.8, but some of the tiles show as skewed with a black band at the bottom. Most likely, these tiles are smaller than the recorded tile dimensions.
Change History (2)
comment:1 Changed 9 years ago by mlinkert
- Keywords ZeissCZIReader added; ZeissLSMReader removed
- Resolution set to fixed
- Status changed from new to closed
comment:2 Changed 9 years ago by Melissa Linkert <melissa@…>
- Remaining Time set to 0
(In [6d0b9dd75e5370531155f0ab033ed7aae228df26/bioformats.git] on branch develop) Zeiss CZI: fix assembly of overlapping tiles
Fixes #12843.
Fixed with: https://github.com/openmicroscopy/bioformats/pull/1787