    initial v1  
    1 When calling `imp.getImageStack().getProcessor(i)` for i>0 on an ImagePlus imp, there is a discrepancy between the behavior depending on how Bio-Formats opened that ImagePlus. If the ImagePlus is virtual, the returned processor has no associated calibration table. But if the ImagePlus is non-virtual, or i==0, then the calibration table is present. 
     1When calling `imp.getImageStack().getProcessor(i)` for i>1 on an ImagePlus imp, there is a discrepancy between the behavior depending on how Bio-Formats opened that ImagePlus. If the ImagePlus is virtual, the returned processor has no associated calibration table. But if the ImagePlus is non-virtual, or i==1, then the calibration table is present. 
    22 
    33This results in the method ImageProcessor.getPixelValue(int, int) failing to return a properly calibrated value in the problem cases. 