Task #12711 (closed)
Opened 9 years ago
Closed 9 years ago
BUG: Error in Measurement Tool
Reported by: | pwalczysko | Owned by: | jburel |
---|---|---|---|
Priority: | critical | Milestone: | 5.1.0-m4 |
Component: | Insight | Version: | 5.1.0-m1 |
Keywords: | n.a. | Cc: | ux@… |
Resources: | n.a. | Referenced By: | n.a. |
References: | n.a. | Remaining Time: | n.a. |
Sprint: | n.a. |
Description
In Measurement Tool, when
- draw a line on a non-default calibrated image (see below)
- select the line and
- go to Graph, Intensity View or IV Results tabs
- observe "Error while analysing the data occured" dialog
Image is ID 23002 on trout merge, user-4 read-only-1.
It is test_images_good/EM-data/EMD-2225.map.
The default units are Angstroms.
Is this expected atm ?
Change History (1)
comment:1 Changed 9 years ago by dlindner
- Resolution set to fixed
- Status changed from new to closed
Note: See
TracTickets for help on using
tickets.
You may also have a look at Agilo extensions to the ticket.
Fixed by: https://github.com/openmicroscopy/openmicroscopy/pull/3387