id summary reporter owner description type status priority milestone component version resolution keywords cc drp_resources i_links o_links remaining_time sprint 12848 Bug: VSI multi-channel fluorescent images fail omero-qa mlinkert "See [https://www.openmicroscopy.org/qa2/qa2/qa/feedback/11039/] and https://www.openmicroscopy.org/community/viewtopic.php?f=13&t=7501&start=20#p15678. CellSensReader fails on multi-channel fluorescent data with [[BR]] {{{ sbesson@necromancer ~ $ ./bftools5.1.0/showinf Image_01.vsi Checking file format [CellSens VSI] Initializing reader CellSensReader initializing Image_01.vsi Exception in thread ""main"" java.lang.IllegalArgumentException: Invalid C index: 1/1 at loci.formats.FormatTools.getIndex(FormatTools.java:410) at loci.formats.FormatTools.getIndex(FormatTools.java:337) at loci.formats.FormatReader.getIndex(FormatReader.java:1083) at loci.formats.in.CellSensReader.initFile(CellSensReader.java:805) at loci.formats.FormatReader.setId(FormatReader.java:1395) at loci.formats.ImageReader.setId(ImageReader.java:835) at loci.formats.ReaderWrapper.setId(ReaderWrapper.java:651) at loci.formats.tools.ImageInfo.testRead(ImageInfo.java:988) at loci.formats.tools.ImageInfo.main(ImageInfo.java:1070) }}}" task closed major 5.1.2 Bio-Formats 5.1.0 fixed CellSensReader olivier.burri@… 0