Task #13097 (closed)
Opened 8 years ago
Closed 8 years ago
BUG: Don't crash Insight on wrong metadata
Reported by: | dlindner | Owned by: | dlindner |
---|---|---|---|
Priority: | major | Milestone: | Unscheduled |
Component: | Insight | Version: | OMERO-5.2.0 |
Keywords: | n.a. | Cc: | |
Resources: | n.a. | Referenced By: | n.a. |
References: | n.a. | Remaining Time: | n.a. |
Sprint: | n.a. |
Description
See https://www.openmicroscopy.org/qa2/qa/feedback/16888/
Apparently Insight crashes if there's something wrong with the metadata and the units can't be converted. This should be caught in another way.
Change History (1)
comment:1 Changed 8 years ago by dlindner
- Resolution set to fixed
- Status changed from new to closed
Note: See
TracTickets for help on using
tickets.
You may also have a look at Agilo extensions to the ticket.
Fixed by: https://github.com/openmicroscopy/openmicroscopy/pull/4323
Note: The description of this ticket is actually wrong. Having other units than referenceframe for image acquisition position is valid, so above mentioned PR removes the attempt to convert them.