Task #13224 (closed)
Opened 8 years ago
Closed 8 years ago
BUG: ZeissCZIReader (PixelData issues)
Reported by: | bramalingam | Owned by: | mlinkert |
---|---|---|---|
Priority: | minor | Milestone: | Unscheduled |
Component: | Bio-Formats | Version: | Bio-Formats-5.1.8 |
Keywords: | ZeissCZIReader, our-fault | Cc: | h.thoen@… |
Resources: | n.a. | Referenced By: | https://trello.com/c/y6KpD3sU/4-czi-tickets |
References: | n.a. | Remaining Time: | n.a. |
Sprint: | n.a. |
Description
ref: https://www.openmicroscopy.org/qa2/qa/feedback/17173/
Testing setup : Version of Bio-Formats : 5.1.9 (FIJI)
1) Blank Image was seen post import. (Zero valued pixels)
2) Brightfield (RGB) image being read as a 3 channel Image.
Change History (2)
comment:1 Changed 8 years ago by sbesson
- Milestone changed from B-F-5.2.0 to Unscheduled
- Referenced By set to https://trello.com/c/y6KpD3sU/4-czi-tickets
comment:2 Changed 8 years ago by mlinkert
- Keywords ZeissCZIReader our-fault added
- Resolution set to fixed
- Status changed from new to closed
Note: See
TracTickets for help on using
tickets.
You may also have a look at Agilo extensions to the ticket.
Bug confirmed with 5.1.9; no longer present in 5.2.2. See https://github.com/openmicroscopy/data_repo_config/pull/131