Description
http://qa.openmicroscopy.org.uk/qa/feedback/3944/
Comment: I am trying to look at how a line profile changes through Z. It's very useful to have the Z-slider on the measurement tool graph pane, but using it is a bit buggy. When you change the Z focus is given back to the image window when it re-draws. This means that when you are using the up and down arrows to change Z from the measurement tool it takes a couple of clicks to move 1 Z. If you do this repeatedly the whole of insight locks up until you force close. Also, as a side note, it would be nice to display the current Z on this slider.
Attachments (2)
Change History (15)
comment:1 Changed 8 years ago by jburel
comment:2 Changed 8 years ago by jmoore
- Component changed from from QA to Insight
comment:3 Changed 8 years ago by jburel
- Milestone changed from Unscheduled to OMERO-Beta4.4
Changed 8 years ago by jburel
Changed 8 years ago by jburel
comment:4 Changed 8 years ago by Jean-marie Burel <j.burel@…>
(In [8da58141ea16e1be6f1ed3f3ad3ee80329698098/ome.git]) Display selected z/t in Graph pane (see #6569)
Display the select z-section or timepoint the status bar of the
measurement tool when modifying the plane using the sliders
available in the graph pane.
comment:5 Changed 8 years ago by jburel
- Cc jburel added
- Owner changed from jburel to saloynton
Scott, could you follow that up with Michael?
comment:6 Changed 8 years ago by saloynton
Sure no problem I will arrange to drop by asap with the demo fix.
comment:7 Changed 8 years ago by saloynton
- Sprint set to 2012-01-17 (6)
comment:8 Changed 8 years ago by saloynton
- Remaining Time set to 0.25
comment:9 Changed 8 years ago by jburel
- Sprint changed from 2012-01-17 (6) to 2012-01-31 (7)
Moved from sprint 2012-01-17 (6)
comment:10 Changed 8 years ago by jburel
- Owner changed from saloynton to jburel
- Status changed from new to accepted
comment:11 Changed 8 years ago by jburel
- Remaining Time changed from 0.25 to 0
- Status changed from accepted to closed
comment:12 Changed 8 years ago by jburel <j.burel@…>
- Resolution set to fixed
(In [6688ea274989e981dce6778d4460d32d0c80e645/ome.git] on branch develop) Fix problem with slider in GraphPane? view
Indicates the selected z and/or t when moving the slider.
Analyzes the shape when releasing the slider
Analyzes and indicates the selected plane when using the up/down
arrow (close #6569)
comment:13 Changed 8 years ago by jburel <j.burel@…>
(In [650bc3a1b39eb5ab4312d31033a2fabc67b4364e/ome.git] on branch develop) Update value when moving slider
Synchronize plane value and intensity values
in the intensity view (see #6569)
It seems to be an issue on Windows. I did not notice the problem on mac