Task #12943 (closed)
Bug: bfconvert can generate broken PNGs
Reported by: | mtbcarroll | Owned by: | mlinkert |
---|---|---|---|
Priority: | minor | Milestone: | 5.1.3 |
Component: | Bio-Formats | Version: | 5.1.2 |
Keywords: | APNGWriter | Cc: | bf@…, Tjelvar.Olsson@…, pwalczysko |
Resources: | n.a. | Referenced By: | n.a. |
References: | n.a. | Remaining Time: | 0.0d |
Sprint: | n.a. |
Description (last modified by mtbcarroll)
With Bio-Formats 5.1.2,
bfconvert test_images_good/ome-tiff/multi-channel-4D-series.ome.tif 'S%s_C%c_Z%z_T%t.png'
seems to work fine but for S0_C0_Z0_T0.png libpng-based viewers report,
libpng warning: acTL: CRC error
and the resulting PNG file is smaller than from old versions. I can't actually get GraphicsMagick to open the file at all.
This regression appears to have occurred between versions 4.4.4 and 4.4.5.
Change History (4)
comment:1 Changed 9 years ago by mtbcarroll
- Description modified (diff)
- Owner set to mlinkert
comment:2 Changed 9 years ago by mlinkert
- Cc pwalczysko added
- Milestone changed from Unscheduled to 5.1.3
comment:3 Changed 9 years ago by mlinkert
- Resolution set to fixed
- Status changed from new to closed
comment:4 Changed 8 years ago by Melissa Linkert <melissa@…>
- Remaining Time set to 0
(In [8cb3363d4a6fb9be5900fa747f7e731b117a08fb/bioformats.git] on branch develop) APNG export: fix frame count and footer writing
Fixes #12943.
Bumping up to 5.1.3 given the severity. This might merit a new (or expanded?) manual testing scenario as well.